Campbell SP-LITE Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Medição, teste e controlo Campbell SP-LITE. SP–Lite Silicon Pyranometer Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
INSTRUCTION MANUAL
SP Lite2
Pyranometer
February 2014
Copyright © 2010 - 2014
Campbell Scientific (Canada) Corp.
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - INSTRUCTION MANUAL

INSTRUCTION MANUALSP Lite2PyranometerFebruary 2014Copyright © 2010 - 2014Campbell Scientific (Canada) Corp.

Página 2

SP Lite2 Silicon Pyranometer1. Attach the mounting arm to the tripod or tower at the required height.2. Loosely attach the SP Lite2 to the mounting ar

Página 3 - WARRANTY AND ASSISTANCE

SP Lite2 Silicon Pyranometer5.1 Datalogger Input Range CodesNormally the 500 mV range for the 21X and CR7, the 250 mV range for the CR800, CR1000, CR1

Página 4 - Table of Contents

SP Lite2 Silicon Pyranometer'{CR1000}'\\\\\\\\\\\\\\\\\\\\\\\\\ DECLARATIONS /////////////////////////Public W_m2'\\\\\\\\\\\\\\\\\\\\\

Página 5

SP Lite2 Silicon Pyranometer5: If time is (P92)1: 0 Minutes (Seconds --) into a2: 30 Interval (same units as above)3: 10 Set Outpu

Página 6 - 1.2 Spectral Properties

SP Lite2 Silicon PyranometerWiring for Examples 3 and 4Colour Function CR1000 Channels CR10X ChannelsRed Radiation Signal S.E. Channel 1 S.E. Channel

Página 7

SP Lite2 Silicon Pyranometer; Set negative values to zero2: If (X<=>F) (P89)1: 1 X Loc [ MJ_m2 ]2: 4 <3: 0 F4: 30

Página 8 - 2. Sensor Specifications

SP Lite2 Silicon Pyranometer6. MaintenanceThe SP Lite2 is an ‘all weather’ instrument and is very stable, but should be handled with care. It require

Página 10 - 5. Datalogger Programming

WARRANTY AND ASSISTANCE This equipment is warranted by CAMPBELL SCIENTIFIC (CANADA) CORP. ("CSC") to be free from defects in material

Página 11

SP Lite2 Silicon PyranometerTable of Contents1. General Description...11.1 Electrical Properties...

Página 12 - ; Set negative values to zero

SP Lite2 Silicon PyranometerSP Lite2 Silicon PyranometerThe SP Lite2 measures incoming solar radiation (sun plus sky radiation) with a photodiode dete

Página 13

SP Lite2 Silicon PyranometerFIGURE 2. SP Lite2 Electrical Circuit1.2 Spectral PropertiesThe spectral properties of the SP Lite2 are mainly determined

Página 14

SP Lite2 Silicon PyranometerBoth the spectral sensitivity and the photodiode sensitivity of the SP Lite2 will change with temperature, and the separat

Página 15

SP Lite2 Silicon Pyranometer2. Sensor SpecificationsElectricalNominal Impedance: > 10:Response Time: <1 second (at 95%)Sensitivity: (see Ce

Página 16 - 7. Troubleshooting

SP Lite2 Silicon Pyranometer3. Installing the SP Lite2The SP Lite2 with leveling instrument are attached to a tripod or tower using one of two mountin

Comentários a estes Manuais

Sem comentários