Campbell 229 Especificações Página 1

Consulte online ou descarregue Especificações para Medição, teste e controlo Campbell 229. Campbell 229 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Water Potential Sensor

229 Heat Dissipation Matric Water Potential SensorRevision: 5/09Copyright © 2006-2009Campbell Scientific, Inc.

Página 2 - Warranty and Assistance

229 Heat Dissipation Matric Water Potential Sensor FIGURE 4-1. Schematic of Connections for Measurement of a 229 Sensor 5. Example Programs 5.1 Ch

Página 3 - 229 Sensor Table of Contents

229 Heat Dissipation Matric Water Potential Sensor 5.2 Adjusting for Thermal Properties of Sensor During Early Heating Times The discussion presented

Página 4 - List of Tables

229 Heat Dissipation Matric Water Potential Sensor The AM16/32B multiplexer in 4x16 mode provides a convenient method to measure up to sixteen 229 sen

Página 5 - Potential Sensor

229 Heat Dissipation Matric Water Potential Sensor 5.5 Example #1 — CR1000 with CE4 and Four 229s Table 5-1 shows wiring information for reading four

Página 6 - 1.2 Measurement Principle

229 Heat Dissipation Matric Water Potential Sensor 'CR1000 SequentialMode Const Num229 = 4 'Enter number of 229 sensors to measure Dim Lo

Página 7

229 Heat Dissipation Matric Water Potential Sensor 5.6 Example #2 — CR1000 with AM16/32-series Multiplexer, CE4 and Sixteen 229 Sensors with Temperat

Página 8 - 3. Installation

229 Heat Dissipation Matric Water Potential Sensor 'CR1000 SequentialMode Const Num229 = 16 'Enter number of 229 sensors to measure Const

Página 9 - 4. Wiring

229 Heat Dissipation Matric Water Potential Sensor 'Measure temperature after 30 second of heating TCDiff(Temp_30sec_C(i),1,mV2_5C,1,Type

Página 10 - 5. Example Programs

229 Heat Dissipation Matric Water Potential Sensor ;{CR10X} ;Program to read 1 229-L sensor ;Reading 1 sensor takes 30 seconds *Table 1 Program 01:

Página 11 - Heating Times

229 Heat Dissipation Matric Water Potential Sensor 8: Excitation with Delay (P22) ;Wait 29 more seconds for next reading 1: 1 Ex Channel

Página 12 - 5.4 Temperature Correction

Warranty and Assistance The 229 HEAT DISSIPATION MATRIC WATER POTENTIAL SENSOR is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in ma

Página 13

229 Heat Dissipation Matric Water Potential Sensor 5.8 Example #4 — CR10X with AM16/32-series, CE4, and Sixteen 229 Sensors Table 5-4 shows wiring in

Página 14

229 Heat Dissipation Matric Water Potential Sensor ;{CR10X} ;Program to read 16 229-L sensors using 1 AM16/32 multiplexer ;and 1 CE4 or CE8 constant c

Página 15 - Correction

229 Heat Dissipation Matric Water Potential Sensor 11: Thermocouple Temp (DIFF) (P14) ;Read thermocouple after 1 second of heating 1: 1 Reps

Página 16

229 Heat Dissipation Matric Water Potential Sensor 22: Sample (P70) ;Sample 16 initial soil temperature readings 1: 16 Reps 2: 3 Loc [ Ti

Página 17

229 Heat Dissipation Matric Water Potential Sensor correspond to the water potential expected during sensor use should be included in the calibration

Página 18

229 Heat Dissipation Matric Water Potential Sensor The dryTΔ value requires that the ceramic be as dry as possible. Sensors cbe dried with desiccant

Página 19

229 Heat Dissipation Matric Water Potential Sensor 0 500 1000 1500 2000600400200020040060010 degrees C16 degrees C18 degrees C22 degrees C24 degrees C

Página 20 - Sixteen 229 Sensors

229 Heat Dissipation Matric Water Potential Sensor 0 100 200 300 400 500200100010020010 degrees C16 degrees C18 degrees C22 degrees C24 degrees C30 de

Página 21

229 Heat Dissipation Matric Water Potential Sensor 2. With the sensor in place, use the TΔfrom the in situ measurement along with the dryTΔ, wetTΔ va

Página 22

229 Heat Dissipation Matric Water Potential Sensor 3. Measurements of sensor temperature response are made periodically to determine if equilibration

Página 23 - 6. Calibration

229 Sensor Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks ta

Página 24 - Temperature

229 Heat Dissipation Matric Water Potential Sensor FIGURE 6-4. Datalogger and Peripheral Connections for 229 Calibration 7. Maintenance The 229 doe

Página 25 - * T

229 Heat Dissipation Matric Water Potential Sensor 8. Troubleshooting Symptom Possible Cause Action Temperature reading is offscale (-6999 or NAN) Th

Página 26

229 Heat Dissipation Matric Water Potential Sensor 28 9. References Flint, A. L., G. S. Campbell, K. M. Ellett, and C. Calissendorff. 2002. Calibrati

Página 28

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Página 29

229 Sensor Table of Contents ii 9. References...28 List of Figures 1-1. 229 Heat Diss

Página 30 - 7. Maintenance

229 Heat Dissipation Matric Water Potential Sensor 1. General Description The 229 Heat Dissipation Matric Water Potential Sensor uses a heat dissipat

Página 31 - 8. Troubleshooting

229 Heat Dissipation Matric Water Potential Sensor Use of the 229 sensor requires a constant current source. Campbell Scientific offers the CE4 and C

Página 32 - 9. References

229 Heat Dissipation Matric Water Potential Sensor A change in the water potential and water content of the ceramic matra corresponding change in the

Página 33

229 Heat Dissipation Matric Water Potential Sensor 2. Specifications 229 Measurement range: -10 to -2500 kPa Measurement 30 seconds typical time:

Página 34

229 Heat Dissipation Matric Water Potential Sensor 3.3 EquilibratioInstallationd the e ceramic pores with liquid water will optimize the hydraulic co

Comentários a estes Manuais

Sem comentários