CS526
ISFET
ph Probe
Issued: 9.6.14
Copyright © 2009-2014 Campbell Scientific, Inc.
Printed under licence by Campbell Scientific Ltd.
CSL 947
Vista de página 0
1 2 3 4 5 6 ... 29 30

Resumo do Conteúdo

Página 1 - CSL 947

CS526 ISFET ph Probe Issued: 9.6.14 Copyright © 2009-2014 Campbell Scientific, Inc. Printed under licence b

Página 2

Appendices A. Importing Short Cut Code ... A-1 A.1 Importing Short Cut Code into a Program Editor ...

Página 3 - Guarantee

CS526 ISFET pH Probe 1. Introduction The CS526 ISFET pH Probe measures pH from 2 to 12 in aqueous or semi-solid solutions. It outputs TTL serial da

Página 4

CS526 ISFET pH Probe The model number and cable length are printed on a label at the connection end of the cable. Check this information against the

Página 5 - PLEASE READ FIRST

User Manual 3. When Short Cut opens, select New Program. 4. Select Datalogger Model and Scan Interval (default of 5 seconds is OK for most applica

Página 6

CS526 ISFET pH Probe 5. Under the Available Sensors and Devices list, select the Sensors | Water | Quality folder. Select CS526 ISFET pH Probe. Cli

Página 7 - Precautions

User Manual 8. If LoggerNet, PC400, or PC200W is running on your PC, and the PC to datalogger connection is active, you can click Finish in Short Cut

Página 8

CS526 ISFET pH Probe Sensor Material: PEEK Weight w/10-ft cable: 318 g (11.2 oz) Dimensions Length: 102 mm (4 in) Diameter: 16 mm (0.63 in)

Página 9 - Contents

User Manual Table 7-2. “Get Data” Command and Response Command Response aMn!<CR> Where: a = probe address (factory default is 1) n = a

Página 10

CS526 ISFET pH Probe 7.2.3.2 SerialOut() Instruction The SerialOut() instruction has the following syntax: SerialOut(ComPort,OutString,WaitString,Num

Página 11 - CS526 ISFET pH Probe

User Manual 7.2.3.4 SplitStr() Instruction The SplitStr() instruction has the following syntax: SplitStr(SplitResult,SearchString,FilterString,NumSp

Página 13

CS526 ISFET pH Probe Problem: Output signal is at its maximum value. Possible reasons: o Probe is not in fluid. o Chip is polluted. o Diaphragm is

Página 14

User Manual • Instability of the reading • Slow calibration • Probe will not calibrate • pH value doesn’t change as expected when changing samples

Página 15 - 6. Specifications

CS526 ISFET pH Probe • Proteins, fats, and oils may be removed by scrubbing in a solution of Terg-A-Zyme (Alconox company), a pepsin solution, or a s

Página 16 - 7.2.1 Get Data Command

Appendix A. Importing Short Cut Code This tutorial shows: • How to import a Short Cut program into a program editor for additional refinement. • H

Página 17

Appendix A. Importing Short Cut Code A-2

Página 18

Appendix B. Example Program The following is a CR1000 program that measures the CS526. This program assumes the CS526 is connected to COM1 (C1 / TX

Página 19 - 8. Troubleshooting

Appendix B. Example Program B-2

Página 20 - 9.1.1 When to Clean

Appendix C. Calibration This calibration process uses pH-7 and pH-4 buffer solutions. Protect the sensing chip from UV radiation during calibration

Página 21 - 9.1.2 Cleaning Procedure

Appendix C. Calibration C.1 Example Calibration Program Following is a simple example program to facilitate the two-point calibration. Although this

Página 23

Guarantee This equipment is guaranteed against defects in materials and workmanship. This guarantee applies for six months from date of delivery. We

Página 24

CAMPBELL SCIENTIFIC COMPANIES Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com  info@campbel

Página 26

PLEASE READ FIRST About this manual Please note that this manual was originally produced by Campbell Scientific Inc. primarily for the North American

Página 28

Precautions DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND TRIPODS, TOWERS, AND ANY ATTACHMENTS TO

Página 30

Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to specific sect

Comentários a estes Manuais

Sem comentários