CSAT3 Three Dimensional Sonic Anemometer
4
2.4 Power Requirements
VOLTAGE SUPPLY: 10 to 16 Vdc
POWER:
2.4 W @ 60 Hz measurement frequency
1.2 W @ 20 Hz measurement frequency
3. Initial Setup
3.1 Factory Settings
Analog Outputs – Off
Execution Parameter – 10 Hz (see Section 10.3 and B.1)
Trigger Source – Internal Clock (see Section 8, 9, and B.1)
SDM Address – 3 (see Section 3.2, 6.1, and 10.3)
RS-232 baud rate – 9600 bps (RS=0) (see Section 12 and Appendix B)
Software RTS – Off (RI=0) (see Section 12 and Appendix B)
Unprompted Output – Off (&=0) (see Appendix B)
The above settings can be changed with a PC, running the CSAT3 PC support
software (CSAT32.EXE), and the RS-232 cable. A copy of the CSAT3 PC support
software is available from the Campbell Scientific web site in the Support|Downloads
section.