Campbell HC2S3 Manual Página 1

Consulte online ou descarregue Manual para Medição, teste e controlo Campbell HC2S3. Campbell HC2S3 Product manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - HC2S3 Temperature

HC2S3 Temperature and Relative Humidity ProbeRevision: 10/12 Copyright © 1990-2012Campbell Scientific, Inc.

Página 2

Model HC2S3 Temperature and Relative Humidity Probe 4.2 Step 2 — Use SCWin Short Cut to Program Datalogger and Generate Wiring Diagram The simplest m

Página 3 - Warranty

Model HC2S3 Temperature and Relative Humidity Probe 3. Select HC2S3 Temperature and Relative Humidity Sensor and choose either constant power or pane

Página 4 - Assistance

Model HC2S3 Temperature and Relative Humidity Probe 5. Choose the outputs for the AirTC and RH and then select finish. 6. Wire according to the wi

Página 5 - Table of Contents

Model HC2S3 Temperature and Relative Humidity Probe 5. Overview The HC2S3 is a digital probe with 0 to 1 V linear output signals for temperature and

Página 6

Model HC2S3 Temperature and Relative Humidity Probe The HC2S3-L's cable can terminate in: • Pigtails that connect directly to a Campbell Scienti

Página 7 - Humidity Probe

Model HC2S3 Temperature and Relative Humidity Probe Power Consumption: <4.3 mA @ 5 V <2.0 mA @ 12 V Supply Voltage (using CSI cable): 5 t

Página 8 - 4. Quickstart

Model HC2S3 Temperature and Relative Humidity Probe 6.2 Relative Humidity Sensor Sensor: ROTRONIC Hygromer® IN1 Relative Humidity Measurement Range:

Página 9

Model HC2S3 Temperature and Relative Humidity Probe 7. Installation 7.1 Siting Sensors should be located over an open level area at least 9 m (EPA)

Página 10

Model HC2S3 Temperature and Relative Humidity Probe The HC2S3 draws approximately 2 mA powered from 12V. The HC2S3 can be continuously powered from t

Página 11

Model HC2S3 Temperature and Relative Humidity Probe TABLE 7-2. Connections for Differential Measurements Color Description CR1000, CR3000, C

Página 13 - 5. Overview

Model HC2S3 Temperature and Relative Humidity Probe The HC2S3 output scale is 0 to 1000 mV for the temperature range of -40° to +60°C and 0 to 1000 m

Página 14 - 6. Specifications

Model HC2S3 Temperature and Relative Humidity Probe CR1000 program using single-ended measurements 'CR1000 program to measure HC2S3 with single-e

Página 15 - 6.1 Temperature Sensor

Model HC2S3 Temperature and Relative Humidity Probe 4: Volt (SE) (P1) 1: 1 Reps 2: 25 2500 mV 60 Hz Rejection Range 3: 4 SE Channel 4:

Página 16

Model HC2S3 Temperature and Relative Humidity Probe CR1000 program using single-ended measurements in Slow Sequence scan The following program example

Página 17 - 7. Installation

Model HC2S3 Temperature and Relative Humidity Probe TABLE 7-6. Wiring for Differential Measurement Examples Color Description CR1000 CR10(X) Brown T

Página 18

Model HC2S3 Temperature and Relative Humidity Probe 2: Volt (Diff) (P2) 1: 1 Reps 2: 25 2500 mV 60 Hz Rejection Range 3: 2 DIF

Página 19 - 7.4 Programming

Model HC2S3 Temperature and Relative Humidity Probe The signal reference (yellow) and the power ground (gray) are in common inside the HC2S3. When th

Página 20

Model HC2S3 Temperature and Relative Humidity Probe 9. Troubleshooting Symptom: -9999, NAN, -40°C, or 0 % relative humidity 1. Check that the sensor

Página 21

Model HC2S3 Temperature and Relative Humidity Probe 22 Lowe, P. R., 1977: An approximating polynomial for the computation of saturation vapor pressur

Página 22

Appendix A. Absolute Humidity The HC2S3 measures the relative humidity. Relative humidity is defined by the equation below: 100 eeRHs∗= (A-1) wh

Página 23

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Página 24

Appendix A. Absolute Humidity A-2 CR1000 Program that Computes Vapor Pressure and Saturation Vapor Pressure 'CR1000 program that calculates Vapo

Página 25

Appendix B. Changing the HC2S3 Settings B.1 HC2S3 Default Settings The HC2S3 probe has the following default settings, which can be changed as desc

Página 26 - 8. Sensor Maintenance

Appendix B. Changing the HC2S3 Settings B.2 Software and Hardware Requirements For temperature (Analog Output 2), the HC2S3 default range is -40 to

Página 27 - 10. References

Appendix B. Changing the HC2S3 Settings Click on “Device Manager”, select “Analog Outputs” to see the following screen: Change the lower and upper r

Página 28

Appendix B. Changing the HC2S3 Settings B-4 Example measurement instructions for CR1000 datalogger, with the sensor wired to SE channel 2: Public Air

Página 29 - ∗= (A-1)

Appendix C. HC2S3 Digital Communications C.1 HC2S3 Digital Interface Specifications The HC2S3 has a UART (Universal Asynchronous Receiver Transmitt

Página 30 - A.1 Measurement Below 0°C

Appendix C. HC2S3 Digital Communications Command Format: { ID Adr RDD Chksum or } CR Answer format: { ID Adr RDD Chksum or } C

Página 31 - Settings

Appendix C. HC2S3 Digital Communications C.3 RS-485 Communications using an MD485 RS-485 Interface The HC2S3 can be interfaced to a CSI datalogger t

Página 32

Appendix C. HC2S3 Digital Communications Sensor Wiring: E2-05XX-MOD Cable MD485 CR1000 Blue A Red B Green 12V Gray/Yellow G Clear

Página 33

Appendix C. HC2S3 Digital Communications C.4 RS-485 Communications using an SDM-SIO1 Serial I/O Module The HC2S3 can be interfaced to a CSI datalogg

Página 34

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Página 35 - Communications

Appendix C. HC2S3 Digital Communications C-6 Example CR1000 Program: 'CR1000 Program 'Declare variables Public SerialIndest As String * 100

Página 37 - Interface

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Página 38

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Página 39 - Serial I/O Module

Table of Contents ii Appendices A. Absolute Humidity ...A-1 A.1 Measurement Below 0°C...

Página 40

Model HC2S3 Temperature and Relative Humidity Probe 1. Introduction The HC2S3 is a rugged, accurate temperature/RH probe that is ideal for long-term

Página 41

Model HC2S3 Temperature and Relative Humidity Probe 3.1 Ships With The HC2S3 ships with: (1) 27731 Gill Radiation Shield Hex Plug (1) Calibration Car

Página 42

Model HC2S3 Temperature and Relative Humidity Probe FIGURE 4-1. HC2S3 and 41003-5 Radiation Shield on a tripod mast FIGURE 4-2. HC2S3 and 41003-5

Comentários a estes Manuais

Sem comentários