Campbell Met One 034A-L Manual do Operador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 75
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
12
Installation, Operation and Maintainance of Automatic Meteorological Stations
Introduction
Figure 1: Met Station
The main components of the Met Station are:
• Tripod(partlymanufacturedlocally)
• ProtectiveenclosureENC12/14
• CR10Xstorageandcontrolmodule(insidetheprotectiveenclosure)
• PS12LApowersupply(includingrechargeablebattery;insidetheprotectiveenclosure)
• MSX10RSolarpanel
• Sensors
• SM4Mstoragemodule(asingleunitusedformultiplestations)
• CR10KDkeyboarddisplay(asingleunitusedformultiplestations)
Figure 2 displays the CR10X storage and control module, which is the actual data logger. The various sensors will
be connected to the green terminal strip, following a wiring schedule presented later in this manual.
Lighting Rod
Pyranometer
Wind Vane
Anemometer
Solar Panel
Temperature & RH
Sensor
Protective
Enclosure (Having
D. Logger & Power
Supply)
Lighting Rod
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 74 75

Comentários a estes Manuais

Sem comentários