2
Establishing Cellular Service
RavenXTV
Call Verizon at 1-888-384-1775 and set up either a
static or dynamic IP account. A static IP account
eliminates the need for a third party Dynamic Domain
Name System (DDNS) such as IP manager. e DDNS
translates the domain name to a dynamic IP address
so that the modem can be contacted as if it had a static
IP address. When setting up the account, you will need
the ESN number, which is listed on the modem’s label.
You will also need to request the unrestricted IP. Veri-
zon’s Broadband Plan is recommended.
RavenXTG
Call AT&T at 1-800-331-0500 and ask for an unre-
stricted data account for a GPRS modem. Either a
static IP account or a dynamic IP account needs to be
established. A er the account has been set up, mobile
termination needs to be con gured onto the account
to make the modem accessible through the Internet.
is is done by adding an I2gold APN
2
or custom APN
3
to the account. A data account with an I2gold APN
will have a Static IP address.
A er establishing service, AT&T will provide a SIMM
card for each modem. In some cases, the SIMM card
can be picked up at the local AT&T store.
Datalogger Site Equipment
Digital Cellular Modem
e RavenXTV and RavenXTG are con gured using
the following so ware:
• Airlink AceManager so ware—activates the
modem and con gures the generic parameters
of the modem.
• Campbell Scientific’s Raven CDMA Tem-
plate (RavenXTV) or Raven GPRS Template
(RavenXTG)—used with Airlink AceManager
so ware to con gure the modem. e template
sets up the Raven serial interface, which is speci c
to Campbell Scienti c systems.
e AceManager so ware, Raven CDMA Template, and
Raven GPRS Template are available, at no charge, from:
www.campbellsci.com/downloads
Datalogger Connections
All of our contemporary and many of our retired data-
loggers are compatible. e datalogger connects with
the modem using one of the following devices:
• 18663 Null Modem Cable—connects the modem
directly to the datalogger’s RS-232 port. is cable
is the only option available for connecting the
modem to a CR200(X)-series datalogger.
• SC105 DCE Interface—connects the modem to
the datalogger’s CS I/O port via an SC12 cable.
e SC105 is recommended for PB® data-
loggers when the RS-232 port is unavailable.
• SC932A DCE Interface—connects the modem
to the datalogger’s CS I/O port via an SC12 cable.
e SC932A is recommended for mixed-array
dataloggers when the RS-232 port is unavailable.
Power Considerations
A power cable shipped with the modem connects
to the datalogger’s 12 V or switched 12 V terminal.
Connection to the switched 12 V terminal allows the
datalogger to switch power to the modem during
scheduled transmission intervals, thereby conserving
power. When using the switched 12 V terminal, the
modem can be powered with a BP12 battery, CH100
regulator, and SP10 solar panel. For help on analyzing
your system’s power requirements, refer to our Power
Supply product brochure or application note.
One of the above is required to connect the datalogger to the
modem. The best choice for your application depends on the
datalogger you are using.
2
At one time, feature code G821 was used instead of the I2gold APN. Feature code G821 has been discontinued, and all RavenXTGs need either
an I2gold APN or custom APN.
3
A custom APN may o er more e cient routing and better security for large cellular phone networks. It will take four to six weeks for AT&T to
develop a custom APN and cost about $250.00.
18663
SC932A
SC105