Redwing Digital Cellular Modem
9
Another option is to power the transceiver for the first 15 minutes of each hour.
;{CR10X}
;
*Table 1 Program
01: 10 Execution Interval (seconds)
1: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 41 Set Port 1 High
2: If time is (P92)
1: 15 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 51 Set Port 1 Low
*Table 2 Program
02: 0.0000 Execution Interval (seconds)
*Table 3 Subroutines
End Program
Whatever the time that the program powers the transceiver, the station must be
called while the transceiver is on; it cannot answer a call at other times.