HMP50 Temperature and
Relative Humidity Probe
Revision: 10/09
Copyright © 1995-2009
Campbell Scientific, Inc.
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - Relative Humidity Probe

HMP50 Temperature andRelative Humidity ProbeRevision: 10/09Copyright © 1995-2009Campbell Scientific, Inc.

Página 2 - Warranty and Assistance

HMP50 Temperature and Relative Humidity Probe Black Temperature Signal White Relative Humidity Signal Blue Signal & Power Reference Br

Página 3 - HMP50 Table of Contents

HMP50 Temperature and Relative Humidity Probe The temperature and relative humidity signals from the HMP50 are measured using two single-ended analog

Página 4

HMP50 Temperature and Relative Humidity Probe BeginProg Scan(5,Sec,1,0) 'HMP50 Temperature & Relative Humidity Sensor measurements AirTC a

Página 5 - Humidity Probe

HMP50 Temperature and Relative Humidity Probe 6. Long Lead Lengths Long lead lengths cause errors in the measured temperature and relative humidity.

Página 6 - 2.1 Temperature Sensor

HMP50 Temperature and Relative Humidity Probe When the air temperature increases, so does the saturation vapor pressure. Conversely, a decrease in ai

Página 7 - 3. Installation

HMP50 Temperature and Relative Humidity Probe 'CR1000 Public AirTC Public RH Public VP DataTable(Table1,True,-1) DataInterval(0,60,Min,0) Ave

Página 8

HMP50 Temperature and Relative Humidity Probe ;Limit the maximum value of relative humidity ;to 1 (expressed as a fraction). ; 03: If (X<=>F) (

Página 9

HMP50 Temperature and Relative Humidity Probe Shipping Cap(remove prior to installation)Protective Cap and Filter 9598 RH ChipFIGURE 6. Exploded Vie

Página 10 - Clear Shield

HMP50 Temperature and Relative Humidity Probe 14

Página 12 - 5.2 Example for CR10X

Warranty and Assistance The HMP50 TEMPERATURE AND RELATIVE HUMIDITY PROBE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materia

Página 13 - 7. Absolute Humidity

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Página 14

HMP50 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for

Página 15

HMP50 Table of Contents ii Tables 1. Recommended Lead Lengths... 1 2. Datalogger C

Página 16 - 8. Maintenance

HMP50 Temperature and Relative Humidity Probe 1. General The HMP50 Temperature and Relative Humidity probe contains a Platinum Resistance Temperature

Página 17 - 9. References

HMP50 Temperature and Relative Humidity Probe 2.1 Temperature Sensor Sensor: 1000 Ω PRT, DIN 43760B Temperature Measurement Range: -40°C to +60°C T

Página 18

HMP50 Temperature and Relative Humidity Probe 3. Installation 3.1 Siting Sensors should be located over an open level area at least 9 m (EPA) in dia

Página 19

HMP50 Temperature and Relative Humidity Probe Yellow Shipping Cap (remove before installation) FIGURE 1. HMP50 as Shipped FIGURE 2. HMP50 and 4130

Página 20

HMP50 Temperature and Relative Humidity Probe FIGURE 3. HMP50 and 41303-5A Radiation Shield on a CM202 Crossarm FIGURE 4. HMP50 and 41303-5A Ra