Model HFP01SC Self-Calibrating Soil Heat Flux Plate
15: End (P95)
;Compute in-situ calibration.
;
16: If time is (P92)
1: 39 Minutes (Seconds --) into a
2: 180 Interval (same units as above)
3: 30 Then Do
17: Do (P86)
1: 28 Set Flag 8 Low
18: Beginning of Loop (P87)
1: 0 Delay
2: 6 Loop Count
19: Z=X (P31)
1: 7 -- X Loc [ shf_mV_1 ]
2: 31 -- Z Loc [ mV_end_1 ]
20: Z=X*Y (P36)
1: 37 -- X Loc [ V_Rf_1 ]
2: 37 -- Y Loc [ V_Rf_1 ]
3: 13 -- Z Loc [ cal_1 ]
21: Z=X*F (P37)
1: 13 -- X Loc [ cal_1 ]
2: 128.7 F
3: 13 -- Z Loc [ cal_1 ]
22: Z=X+Y (P33)
1: 19 -- X Loc [ mV_0_1 ]
2: 31 -- Y Loc [ mV_end_1 ]
3: 43 Z Loc [ work ]
23: Z=X*F (P37)
1: 43 X Loc [ work ]
2: .5 F
3: 43 Z Loc [ work ]
24: Z=X-Y (P35)
1: 43 X Loc [ work ]
2: 25 -- Y Loc [ mV_180_1 ]
3: 43 Z Loc [ work ]
25: Z=ABS(X) (P43)
1: 43 X Loc [ work ]
2: 43 Z Loc [ work ]
26: Z=X/Y (P38)
1: 13 -- X Loc [ cal_1 ]
2: 43 Y Loc [ work ]
3: 13 -- Z Loc [ cal_1 ]
27: End (P95)
28: End (P95)
29: End (P95)
End Program
-Input Locations-
1 shf_1 1 1 1
2 shf_2 0 0 0
3 shf_3 0 0 0
4 shf_4 0 0 0