CS450/CS455 Pressure Transducer
Compensated Temperature: 0 to 60°C
Temperature Accuracy: ±0.2°C
Maximum Cable Length: SDI-12 - one sensor connected to a single port can
communicate up to approximately 1500 ft. (457 m)
10 sensors connected to a single port, each
sensor can have up to 200 ft. (60 m)
RS-232 - 50 ft. (15 m)
Cable Type: 5 Conductor, 26 AWG
Hytrel Jacket
Body Material: CS450 – 316L Stainless Steel
CS455 – Titanium
Element Material: CS450 – 316L Stainless Steel
CS455 – Hastelloy
Top Cone Material: Delrin
Dimensions: Length 8.4 in (213.36 mm)
Diameter 0.84 in (21.34 mm)
Distance from pressure sensor interface
(black line etched on housing) to:
End of NPT fitting: 1.13 in. (2.86 cm)
End of standard nose cone: 1.58 in (4 cm)
End of weighted nose cone: 4.56 in (11.59 cm)
Weight: CS450: 0.40 lbs (0.18 kg)
CS455: 0.25 lbs (0.11 kg)
Cable: 0.283 lbs/ft (0.421 kg/m)
* Total ERROR Band (TEB) includes the combined errors due to nonlinearity,
hysteresis, nonrepeatability, and thermal effects over the compensated
temperature range, per ISA S51.1.
** 0.05% FS accuracy not available in the 0 – 2.9 psig range.
3. Configuration
The CS450/CS455 is configured at the factory with default settings:
TABLE 3-1. Factory Settings
SDI-12 Address 0
RS-232 Baud Rate 9600
Pressure/Level Units PSIG
Temperature Units Celsius