Campbell CS616 Manual de Instruções Página 25

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 50
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 24
CS616 and CS625 Water Content Reflectometers
;{CR10X}
;
*Table 1 Program
01: 3600 Execution Interval (seconds)
1: Batt Voltage (P10)
1: 7 Loc [ batt ]
2: CS616 Water Content Reflectometer (P138)
1: 3 Reps
2: 1 SE Channel
3: 6 C6 is first of sequential Control Ports used
4: 1 Loc [ period_1 ]
5: 1.0 Mult
6: 0.0 Offset
3: Polynomial (P55)
1: 3 Reps
2: 1 X Loc [ period_1 ]
3: 4 F(X) Loc [ vwc_1 ]
4: -0.0663 C0
5: -0.0063 C1
6: 0.0007 C2
7: 0.0 C3
8: 0.0 C4
9: 0.0 C5
;
4: If time is (P92)
1: 0000 Minutes (Seconds --) into a
2: 240 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
5: Average (P71)
1: 4 Reps
2: 4 Loc [ vwc_1 ]
*Table 2 Program
02: 0.0000 Execution Interval (seconds)
*Table 3 Subroutines
End Program
-Input Locations-
1 period_1 5 1 1
2 period_2 9 1 1
3 period_3 17 1 1
4 vwc_1 5 1 1
5 vwc_2 9 1 1
6 vwc_3 17 1 1
7 batt 1 0 1
6.4.5.4 CS616 Sample Edlog Program 4
Measure soil temperature with 107 probe and CS616 output period every four
hours. Correct CS616 output period for temperature and write result to
datalogger final storage.
19
Vista de página 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 49 50

Comentários a estes Manuais

Sem comentários