Campbell IRGASON Manual Página 1

Consulte online ou descarregue Manual para Medição, teste e controlo Campbell IRGASON. Campbell IRGASON Product manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 59
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
IRGASON Integrated CO
2
/H
2
O
Open-Path Gas Analyzer and
3D Sonic Anemometer
2/12
Copyright © 2010-2012
Campbell Scientific, Inc.
Vista de página 0
1 2 3 4 5 6 ... 58 59

Resumo do Conteúdo

Página 1

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer2/12Copyright © 2010-2012Campbell Scientific, Inc.

Página 2

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer o The SDM, USB, and RS-485 output options include IRGASON diagnostic data.

Página 3

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer • Standard outputs: o ux, uy, and uz orthogonal wind components o sonic t

Página 4

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Sonic accuracy5 Offset error ux, uy: < ±8 cm·s-1 uz: < 4 cm·s-1 Gai

Página 5

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 5.2 Output Signals Features • EC100 electronics outputs data using: o CS

Página 6

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 5-1(a). IRGASON dimensions, side view FIGURE 5-1(b). IRGASON dime

Página 7

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 5.4 Power Requirements During Power-up and Operation Power requirement Sour

Página 8

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Handle the IRGASON carefully. The optical source may be damaged by rough h

Página 9

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer IRGASON CM250 Leveling Mount (p/n 26559) IRGASONMounting Bracket(p/n 27496)

Página 10

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 6-2. EC100-enclosure mounting bracket mounted on a vert

Página 11

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 8. Mount the IRGASON temperature probe so that it measures temperature at t

Página 13

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer tighten the thumbscrews (see Figure 6-5). The gas analyzer cable is approxi

Página 14

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 6-6. Base of EC100 enclosure Unique calibration information is stor

Página 15

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 3. Connect the IRGASON temperature probe. Unscrew the temperature connecto

Página 16

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer o Analog output: use cable CABLE4CBL-L (p/n 21972) or CABLE2TP-L (p/n 26986

Página 17

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 7.1 Factory Defaults Table 7-1 shows the default value for each setting des

Página 18

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer any integer value between 0 and 14. The value 15 is reserved as an SDM-group

Página 19

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer troubleshooting only. In normal operation, Temperature Sensor is set to Aut

Página 20

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 7.14 ECMon Settings for the IRGASON are easily verified or changed using th

Página 21

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 7-1. Main window of ECMon software 20

Página 22

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer FIGURE 7-2. Setup window in ECMon 7.15 Device Configuration Utility DevCo

Página 23

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Página 24

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 8. EC100 Outputs The EC100 is the IRGASON electronics module that measures

Página 25

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer To use USB or RS-485 output, connect a USB or RS-485 cable from the EC100 to

Página 26

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer The final data element in each row or output array is the signature. The si

Página 27

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer TABLE 8-2. Multipliers and Offsets for Analog Outputs Density (mg m-3) Volt

Página 28

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Remove the wicks during the winter. The wicks will accumulate snow or freez

Página 29

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Wicks are available as listed in Table 9-1. TABLE 9-1. Rain Wick Replacement

Página 30

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 9.3 Gas-Analyzer Window Cleaning The windows of the analyzer should be clea

Página 31

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer rubber seals on the ends of the shroud are clean and in good condition. Pos

Página 32

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 8. Connect a gas tank of known CO2 concentration to a pressure regulator, t

Página 33

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 10. Remove the H2O span gas, and connect a zero air source (no CO2 or H2O)

Página 34

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Página 35

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 16. Enter the known dew point (in C°) in the box labeled Span Dew Point and

Página 36

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer Scrubber bottle cover Scrubber bottle cover FIGURE 9-5. Replacing the desi

Página 37

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 10. Datalogger Programming The datalogger is programmed in the CRBasic lang

Página 38

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer TABLE 10-1. Output Modes for EC100 Instruction OutputMode Data Field Desc

Página 39

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer TABLE 10-3. Bits in the Gas Diagnostic Flag bit hex value decimal Na

Página 40

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 10.2 EC100Configure() Instruction EC100Configure() provides a third option,

Página 41

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer TABLE 10-4. ConfigCmd Values for Setting and Retrieving Settings ConfigCmd

Página 42

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 10.2.1 ConfigCmd 11 Zero-and-span Control To perform zeroing of CO2 and H2O

Página 43

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer output indicates moisture is present, the datalogger can send the EC100Confi

Página 44

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 11. Theory of Operation 11.1 IRGASON Sonic Anemometer The CSAT3 measures w

Página 45

IRGASON Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links

Página 46

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 11.1.2 Temperature The sonically determined speed of sound can be found fro

Página 47

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer The sonic virtual temperature, in degrees Celsius, is given by Eq. (9), wher

Página 48

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 44 11.3 Theory References Kaimal, J. C. and Businger, J. A.: 1963, “A Cont

Página 49

Appendix A. Filter Bandwidth and Time Delay The EC100 measures CO2, H2O, 3-D wind components, and sonic temperature from the IRGASON at 100 Hz and th

Página 50

Appendix A. Filter Bandwidth and Time Delay The EC100 measures gas and wind data at 100 Hz, and 100 Hz data are down-sampled to the datalogger scan r

Página 51

Appendix A. Filter Bandwidth and Time Delay 110Hertz700.00010.0010.010.1110No UnitsEC100 10-Hz Bandwidth Filter10-Hz Bandwidth from a 50-msec Moving

Página 52

Appendix A. Filter Bandwidth and Time Delay A-4

Página 53

Appendix B. Equations Table B-1 lists variables and constants used in the following equations. TABLE B-1. Table of Equation Variables and Constants

Página 54

Appendix B. Equations ()⎟⎟⎠⎞⎜⎜⎝⎛+−⎟⎟⎠⎞⎜⎜⎝⎛+=vvddXXTRPM1000115.273ρ (B-5) Dew Point from Molar Mixing Ratio tmpdtmpddTTT__502.17 97.240−= (B-62) ()⎟⎟

Página 55

Appendix C. Material Safety Data Sheets (MSDS) MSDS are available for chemicals used in IRGASON filters. The MSDS samples below are made available f

Página 56

IRGASON Table of Contents 8. EC100 Outputs ...22 8.1 SDM Output...

Página 58

IRGASON Table of Contents 6-4. Mounting the IRGASON Temperature Probe...11 6-5. EC100 electronics front panel wi

Página 59

IRGASON Table of Contents iv

Página 60

IRGASON Integrated CO2/H2O Open-Path Gas Analyzer and 3D Sonic Anemometer 1. Introduction The IRGASON is an in-situ, open-path, mid-infrared absorpti