Campbell COM300 Manual de Instruções Página 29

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 28
Appendix F. Reading Voice Code Information from a *.DLD File
F-3
F.3 Security Enabled
This last example uses the security code "1234" to allow access to the second
level menu. Notice the characters following the "?" at the beginning of the
character stream. The security code will always be the very first thing in the
imbedded character portion of the *.DLD file.
;|?1234#"56&57&"#
#"53&"#
#"52&"#
>\488&89&109&74&71&71&71&"109&135&86&"
85&$387&122&.\
\4"109&98&191&"85&$1192&.\
This code translates to:
(security code 1234) Input Locations
Ports
Flags
(4 decimal places) Campbell Scientific Datalogger Program (pause)
(pause) (pause) "Datalogger Internal Temperature" Is (input location 3)
Degrees Fahrenheit.
(4 decimal places) "Datalogger Battery Voltage" Is (input location 1)
Volts.
Vista de página 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 39 40

Comentários a estes Manuais

Sem comentários