Campbell COM310 Manual

Consulte online ou descarregue Manual para Redes Campbell COM310. Campbell COM310 Product manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 56
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
COM310
Voice Communications Modem
Revision: 11/11
TIP
RING
GND
CAMPBELL
SCIENTIFIC
INC.
MADE IN USA
S/N
1002
Complies with Part 68, FCC rules. FCC Registration No. B9QUSA-31402-MM-T
Ringer Equivalence 0.5A.Required Connector USOC RJ11C.
This equipment complies with the requirements in Part 15 of FCC Rules for Class A
computing device. Operation of this equipment in a residential area may cause
unacceptable interference to radio and TV reception requiring the operator to take
whatever steps are necessary to correct the interference.
COM310
VOICE SYNTHESIZER
12V
G
Copyright © 2002-2011
Campbell Scientific, Inc.
Vista de página 0
1 2 3 4 5 6 ... 55 56

Resumo do Conteúdo

Página 1 - Voice Communications Modem

COM310Voice Communications ModemRevision: 11/11TIPRINGGNDCAMPBELLSCIENTIFICINC.MADE IN USAS/N1002Complies with Part 68, FCC rules. FCC Registration

Página 2

COM310 Voice Communications Modem Step 3 – Send BASIC_VOICE_2.CR1 to CR1000 1) Download BASIC_VOICE_2.CR1 from CSI web site under Support, Downloads,

Página 3 - Warranty

COM310 Voice Communications Modem Pressing the # key you should hear: C R ONE THOUSAND STATION PRESS ONE TO HEAR A SENSOR VALUE PRESS TWO TO HEAR OR

Página 4 - Assistance

COM310 Voice Communications Modem ' CR1000 ' BASIC_VOICE_2.CR1 ' Send VOICE.TXT to CR1000 before sending this program. ' Progra

Página 5 - COM310 Table of Contents

COM310 Voice Communications Modem ' ***** Subroutines ***** ' Called when calling in: Sub CallInVoice Do VoiceSpeak ("CURRENT STA

Página 6

COM310 Voice Communications Modem ' Monitors a value Sub SubKey1 Do VoiceSpeak ("50MS PRESS SENSOR NUMBER 50MS PRESS STAR TO RETURN&quo

Página 7 - 1. Introduction

COM310 Voice Communications Modem If Flags(mykey) Then VoiceSpeak("ON",0) Else VoiceSpeak("OFF",0) EndIf

Página 8 - 3. Quick Start

COM310 Voice Communications Modem ElseIf (TCvalue_F > 85 AND ArmAlarm) OR ManualAlarm = TRUE Then ManualAlarm = False Alarm = TRUE'

Página 9 - Step 2 – Hardware Setup

COM310 Voice Communications Modem Voice Beg / EndVoice The VoiceBeg / EndVoice instruction pair enclose the code that is executed when the datalogger

Página 10 - Step 5 – Callback

COM310 Voice Communications Modem 4.2 Surge Suppressor If the phone company does not provide surge protection at the datalogger site, you will need t

Página 11

COM310 Voice Communications Modem The COM310 must connect to an analog phone line. Some office environment PBX phone lines are digital and don’t inte

Página 13

COM310 Voice Communications Modem 5.1.1.2 Voice Callback The COM310 gives you the ability to do voice callbacks. You can program a station to call o

Página 14

COM310 Voice Communications Modem The VoiceSpeak code might look like this: TC_1 = Public.AirTemp(1,1) VoiceSpeak ("THE AIR TEMPERATURE WAS"

Página 15

COM310 Voice Communications Modem announced menu; however, the user can respond by pressing a key in the middle of an announcement. If doing concurren

Página 16 - Example Program Description

COM310 Voice Communications Modem The CallOut parameter is a Boolean value that indicates the COM310 mode. When the value returned in this parameter

Página 17 - 4. System Components

COM310 Voice Communications Modem DataTable (TestB,1,1000) DataInterval (0,0,Sec,10) Sample (1,PTemp,IEEE4) Sample (1,TCvalue_F,IEEE4) A

Página 18 - 4.4 Telephone

COM310 Voice Communications Modem 5.2.2.1 Data Callback Instructions The following instructions are used to program a data callback. DialSequence/End

Página 19 - 5.1 Features

COM310 Voice Communications Modem tutorial is a more advanced tutorial for setting up voice callback. Example program files are included for use in t

Página 20 - 5.1.2 Voice Callin

COM310 Voice Communications Modem 5.3.6 Voice Callback LoggerTalk can program a voice callback when associated with a *.dld file that includes a P97

Página 21 - 5.2.1 Voice Instructions

COM310 Voice Communications Modem In LoggerNet a comma represents a 1 second delay. You may need to adjust the number of commas so that the “9” occur

Página 22

COM310 Voice Communications Modem FIGURE 3. COM310 / CR1000 Using Surge Protection Device (where there’s no available Standard RJ11 Connection) 6.2

Página 23 - 5.2.2 Data Callback

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Página 24

COM310 Voice Communications Modem 6.3 Grounding the COM310 System Connect the green 14 AWG grounding wire (provided with the COM310) to the GND termi

Página 25 - 5.3.2 Helps and Tutorials

COM310 Voice Communications Modem 6.4 Telephone Service Telephone companies occasionally make changes in their equipment, operations, or procedures.

Página 26 - 5.3.5 Custom Menu Strings

COM310 Voice Communications Modem Figures 5 and 6 show the wiring for connecting the surge suppressor. Color coding of wires may vary. The important

Página 27 - 5.4 LoggerNet

COM310 Voice Communications Modem FIGURE 6. Side View of Surge Suppressor Wiring 7. Troubleshooting COM310 Voice Systems Following are some possibl

Página 28 - 6. Hardware Installation

COM310 Voice Communications Modem 28 6) LoggerNet Setup configured for the wrong PC modem. 7) LoggerNet configured for a baud rate the station canno

Página 29

Appendix A. Theory of Operation The COM310 modem is used to transmit data over bandwidth-limited channels such as telephone lines by modulating audio

Página 30

This is a blank page.

Página 31 - 6.5 Telephone Transfers

B-1 Appendix B. FCC Warning to Users of Class A Computing Devices This equipment generates, uses, and can radiate radio frequency energy, and if not

Página 32

This is a blank page.

Página 33 - 7.1 No Communications

C-1 Appendix C. IC Information Industry Canada (IC) was formerly known as DOC. CP-01, Issue 8, Part I Section 14.1 “NOTICE: The Industry Canada labe

Página 34 - 7.2 Communications Problems

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Página 35

This is a blank page.

Página 36 - This is a blank page

D-1 Appendix D. Set Rings, AT Parameters D.1 Set Number of COM310 Rings before Answer To program the number of rings before the COM310 answers, use

Página 37 - Class A Computing Devices

Appendix D. Set Rings, AT Parameters D-2 (3) Step 3 (a) Dial the phone number (b) Wait until “Connected” appears at lower-left on screen. You will

Página 38

E-1 Appendix E. CS I/O 9 Pin Serial Port The COM310’s CS I/O port is not a standard RS-232 connection. Pin Description The COM310 modem connects to t

Página 39 - Appendix C. IC Information

Appendix E. CS I/O 9 Pin Serial Port E-2 TABLE E-1. Pin Description ABR = Abbreviation for the function name. PIN = Pin number. O = Signal Out

Página 40

F-1 Appendix F. Reading Voice Code in a *.DLD File When a CR10X, CR23X, or CR510 file is edited and saved in LoggerTalk, the information for voice co

Página 41

Appendix F. Reading Voice Code in a *.DLD File F-2 The above code translates to: Input Locations Ports Flags (four decimal places) Campbell Scientifi

Página 42

Appendix F. Reading Voice Code in a *.DLD File F-3 F.3 Modem Security Enabled LoggerTalk’s Modem Security Code is unrelated to the Datalogger’s *C m

Página 43 - Pin Description

Appendix F. Reading Voice Code in a *.DLD File F-4 This is a blank page.

Página 44

G-1 Appendix G. COM310 Word List G.1 COM310 Word List - Numerical Order 0. ZERO 1. ONE 2. TWO 3. THREE 4. FOUR 5. FIVE 6. SIX 7. SEVEN 8. E

Página 45 - *.DLD File

COM310 Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links t

Página 46 - F.2 Callback Code

Appendix G. COM310 Word List G-2 141. MAXIMUM 142. MERCURY 143. METER 144. METERS 145. MICRO 146. MILES 147. MILLI 148. MINIMUM 149. MINUTE

Página 47 - F.3 Modem Security Enabled

Appendix G. COM310 Word List G-3 303. L 304. LAKE 305. LAYER 306. LINE 307. LOAD 308. LOCATED 309. LOCATION 310. LOGAN 311. M 312. M-R-P 3

Página 48

Appendix G. COM310 Word List G-4 59. AND 209. APPROACH 93. ARE 210. AREA 94. AT 211. AVAILABLE

Página 49

Appendix G. COM310 Word List G-5 85. IS 299. IT 300. J 301. K 44. KEY 136. KILO 77. KILOBYTES 3

Página 50

Appendix G. COM310 Word List G-6 75. SIGNATURE 380. SINCE 178. SITE 6. SIX 16. SIXTEEN 24. SIXT

Página 52

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Página 53

COM310 Table of Contents ii 7. Troubleshooting COM310 Voice Systems ...27 7.1 No Communications ...

Página 54

COM310 Voice Communications Modem 1. Introduction The COM310 is a voice-synthesizer modem that supports the PakBus and mixed-array dataloggers that h

Página 55

COM310 Voice Communications Modem 2. Specifications • Bell 212A, CCITT V.21, and V.32BIS compatible • Full duplex at 9600 and 1200 baud to datalogg

Página 56

COM310 Voice Communications Modem Unlike the CR10X, CR510 and CR23X where voice code is appended to a finished measurement program using LoggerTalk so

Comentários a estes Manuais

Sem comentários