CS100 Barometric Pressure Sensor
7.3.3.3 Edlog Example — CR10X Program
Although this example is for a CR10X, other Edlog dataloggers, such as the
CR510, CR23X, CR7, and 21X are programmed similarly. In the example, the
CR10X datalogger turns on the CS100 one minute before the top of the hour
using a control port. On the hour, the datalogger measures the CS100, and then
it turns the CS100 off.
;{CR10X}
;
*Table 1 Program
01: 1 Execution Interval (seconds)
;Turn on CS100 one minute before the hour
;
1: If time is (P92)
1: 59 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 48* Set Port 8* High
;Measure CS100 at the top of the hour
;
2: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 30 Then Do
3: Volt (SE) (P1)
1: 1 Reps
2: 15 2500 mV Fast Range
3: 6 SE Channel
4: 1 Loc [ P_mb ]
5: 0.2 Multiplier
6: 600 Offset
;Turn off CS100
;
4: Do (P86)
1: 58* Set Port 8* Low
5: End (P95)
6: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
7: Real Time (P77)
1: 0110 Day,Hour/Minute (midnight = 0000)
;Store in high resolution mode to retain 0.01mb resolution
;
8: Resolution (P78)
1: 1 High Resolution