Campbell HMP45C Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Medição, teste e controlo Campbell HMP45C. Campbell HMP45C User guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
HMP45C
Temperature and
Relative Humidity Probe
User Guide
Issued 27.5.09
Copyright
©
1990-2009 Campbell Scientific Inc.
Printed under Licence by Campbell Scientific Ltd.
CSL 373
Vista de página 0
1 2 3 4 5 6 ... 27 28

Resumo do Conteúdo

Página 1 - Relative Humidity Probe

HMP45C Temperature and Relative Humidity Probe User Guide Issued 27.5.09 Copyright © 1990-2009 Campbel

Página 2

HMP45C Temperature and RH Probe 2 2.1 Temperature Sensor Sensor: 1000 Ω PRT, IEC 751 1/3 Class B Temperature Measurement Range: -40°C to +60°C Temp

Página 3 - Guarantee

User Guide 3 Do not overtighten the nut that holds in the probe as the probe could be damaged. Figure 1. HMP45C and 41003-5 Radiation Shield on a T

Página 4

HMP45C Temperature and RH Probe 4 5. Continue to carefully insert the probe a further 10mm, until the shoulder of the larger section is approximately

Página 5 - PLEASE READ FIRST

User Guide 5 1. Do not push the probe so far into the radiation shield that the sensor tip touches the top of the shield. 2. Ensure that your last

Página 6

HMP45C Temperature and RH Probe 6 Table 1. Connections for Single-Ended Measurements Sensor Connection Colour CR10X CR1000, CR3000, CR800,

Página 7 - Contents

User Guide 7 Table 3. Power Connections using PSW12 Peripherals HMP45C PSW12 Peripheral Datalogger Descrip

Página 8

HMP45C Temperature and RH Probe 8 Table 6. Wiring for Single-ended Measurement Examples Description Colour CR1000 CR10(X) Temperature White SE 2 (

Página 9 - Humidity Probe

User Guide 9 CR10(X) Program using Single-Ended Measurement Instructions Using a PSW12 or SW12V on Datalogger ;Turn the HMP45C on. ; 01: Do (P86) 1:

Página 10 - Error ( C)

HMP45C Temperature and RH Probe 10 6. Long Lead Lengths This section describes the error associated with measuring the HMP45C with a single-ended mea

Página 11

User Guide 11 CR1000 Program using Differential Measurement Instructions Using SW12 on Datalogger 'CR1000 program to measure HMP45C with differen

Página 13 - 4. Wiring

HMP45C Temperature and RH Probe 12 ;Measure the HMP45C temperature. ; 03: Volt (Diff) (P2) 1: 1 Reps 2: 5 2500 mV Slow Range ;CR510, CR500 (

Página 14

User Guide 13 in the air has not changed. Thus, the amount of water vapour in the air, relative to saturation, has decreased. Because of the inverse

Página 15 - 5. Example Programs

HMP45C Temperature and RH Probe 14 CR10(X) Program that Computes Vapour Pressure and Saturation Vapour Pressure ;Turn the HMP45C on. ; 01: Do (P86)

Página 16

User Guide 15 ;Turn the HMP45C off. ; 05: Do (P86) 1: 51 Set Port 1 Low ;Compute the saturation vapour pressure. ;The temperature must be in d

Página 17

HMP45C Temperature and RH Probe 16 9. Troubleshooting Symptom: -9999, NAN, -40 deg C, or 0% relative humidity 1. Check that the sensor is wired to t

Página 18 - 6. Long Lead Lengths

Appendix A. Wiring for Older HMP45C Probes Description Colour Temperature Signal Yellow Relative Humidity Signal Blue Signal Reference Purple Po

Página 21

CAMPBELL SCIENTIFIC COMPANIES Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci

Página 22

Guarantee This equipment is guaranteed against defects in materials and workmanship. This guarantee applies for twelve months from date of delivery.

Página 24 - 9. Troubleshooting

PLEASE READ FIRST About this manual Please note that this manual was originally produced by Campbell Scientific Inc. primarily for the North American

Página 26

Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to speci

Página 27

Tables 1. Connections for Single-Ended Measurements....6 2. Connections for Differential Measurements...

Página 28

1 HMP45C Temperature and Relative Humidity Probe 1. General Description The HMP45C Temperature and Relative Humidity probe contains a Platinum Resist

Comentários a estes Manuais