3
Ordering Information
Fuel Temperature
You must order both a fuel temperature stick and a temperature
probe. Typically the fuel temperature stick/probe is measured
along side a fuel moisture sensor/stick (see below). e sensors
can be mounted side-by-side on a Fuel Moisture & Temperature
Mounting Stake (at bottom right).
CS205 10-hour Fuel Temperature Stick (requires a 107-L or
107-LC temperature probe; see below)
Temperature Probes (choose one)
107-L Temperature Probe (-35° to +50°C) with user-speci ed
cable length. Enter cable length, in feet, after the
-L; standard length is 25 feet. Must choose a cable
termination option (see below).
107-LC Temperature Probe (-35° to +50°C) for MetData1
Weather Station. Enter cable length, in feet, after the
-LC; standard length is 25 feet (i.e., 107-LC25).
Cable Termination Options for 107-L (choose one)
-PT Cable terminates in stripped and tinned leads for
direct connection to datalogger’s terminals.
-PW Cable terminates in a connector for attachment
to a prewired enclosure.
Fuel Moisture
You must order both a fuel moisture stick and a moisture probe.
Typically the fuel moisture stick/probe is measured along side
a fuel temperature sensor/stick (see above). e sensors can be
mounted side-by-side on a Fuel Moisture & Temperature Mount-
ing Stake (at right).
10824 10-hour Fuel Moisture Stick (requires a CS505-L or
CS505-LC probe; see below)
Fuel Moisture Probes (choose one)
CS505-L Fuel Moisture Sensor/10-hour Fuel Moisture Stick
with user-speci ed cable length. Enter cable length,
in feet, after the -L; standard length is 25 feet. Must
choose a cable termination option (see below).
CS505-LC Fuel Moisture Sensor/10-hour Fuel Moisture Stick
for MetData1 Weather Station. Enter cable length,
in feet, after the -LC; standard length is 25 feet
(i.e., 107-LC25).
Cable Termination Options for CS505-L (choose one)
-PT Cable terminates in stripped and tinned leads for
direct connection to datalogger’s terminals.
-PW Cable terminates in a connector for attachment
to a prewired enclosure.
Fuel Sensors for RAWS Stations
CS515-QD Fuel Moisture & Temperature Sensor for the RAWS-F
Quick Deployment Fire Weather Station. Sensors
have a 12-foot cable length and are mounted on the
10974 mounting stake.
CS515-LQ Fuel Moisture & Temperature Sensor for the RAWS-P
Permanently M
ounted Station; must specify a fuel
moisture sensor cable length and a temperature
sensor cable length (see below). The sensors are
mounted on the 10974 mounting stake.
Cable lengths for the CS515-LQ
Cable lengths of 25, 50, 75, or 100 (8, 15, 23, o
r 31 m) are
recommended.
-LQ Fuel moisture sensor cable length. Enter the cable
length, in feet, after the -LQ.
-LT Temperature probe cable length. Enter the cable
length, in feet, after the -LT.
Mounting Stake
10974 Fuel Moisture & Temperature Mounting Stake
Replacement Dowels
Dowel replacement is recommended every spring; more frequent
replacement may be required in some environments (i.e., those
with a large number of wet/dry cycles).
10824 10-hour Fuel Moisture Stick
CS205 10-hour Fuel Temperature Stick
The dowels of the fuel moisture stick (model
10824) and fuel temperature stick (model
CS205) are easily replaced in the eld with a
Phillips screwdriver and an adjustable wrench.
The CS515 attaches to the connec-
tors labeled FM/FT on the RAWS
connector panel (shown above).
➤
Comentários a estes Manuais