Specifications
Continued on next page BA31779,000036B -19-20OCT14-1/3
Field Connect™ Gateway
Electrical
Input Voltage—Range, 9–16 V
Fuse—Protect device with 5 A fuse.
Battery
Nominal Voltage—12 V
Rated Capacity—12.0 Ah/0.60 A (20 hr., 1.8 V/cell, at
25 °C (77 °F))
LED Display
A—CELL
B—GPS
C—SAT
D—BATT
E—DIG 1–4
F— FAULT
G—ALG 1–4
H—FRQ 1, 2
I— USB (Multi-colored LED)
J— SER 1, 2
K—SMP 1, 2
PC17702 —UN—20SEP13
LED Display
LED
STATE DESCRIPTION
Solid Connection established
Blinking Attempting connection or unable to connect
CELL (A)
Off
Device not enabled
Solid Connection established
Blinking Attempting connection or unable to connect
GPS (B)
Off
Device not enabled
Solid Connection established
Blinking Attempting connection or unable to connect
SAT (C)
Off
Device not enabled
Solid
Battery connected
Blinking
Critical power state
BATT (D)
Off
Unit not powered
Solid
Device present
Blinking
Channel enabled; no device detected
DIG 1 (E)
Off Channel disabled
Solid
Device present
Blinking
Channel enabled; no device detected
DIG 2 (E)
Off Channel disabled
Solid
Device present
Blinking
Channel enabled; no device detected
DIG 3 (E)
Off Channel disabled
Solid
Device present
Blinking
Channel enabled; no device detected
DIG 4 (E)
Off Channel disabled
Solid N / A
Blinking Urgent Fault
FAULT (F)
Off
No Fault Active
Solid
Device present
Blinking
Channel enabled; no device detected
ALG 1 (G)
Off Channel disabled
Solid
Device present
Blinking
Channel enabled; no device detected
ALG 2 (G)
Off Channel disabled