Campbell LWS-L Manual do Operador Página 33

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 32
AIRMAR WeatherStation 150WX Weather Sensor
RM72004,0000171 -19-07MAY13-1/1
CZ76372,000072E -19-20OCT14-1/1
Theory of Operation
The AIRMAR WeatherStation 150WX weather sensor
provides air temperature, relative humidity, wind speed,
and wind direction. Air temperature, relative humidity,
and wind speed are used to calculate evapotranspiration
(ET), a critical measurement in irrigation planning and
scheduling.
A—Weather Sensor
B—Sensor Extension Piece
C—Wiring Harness with 8-Pin
Connector
PC16619 —UN—25FEB13
Specifications
NOTE: Specifications are for a new sensor. System
performance may vary based on application.
Measurements
Measurement Time: 10 ms
Power: 2.5 VDC at 2 mA, to 5 VDC at 7 mA
Output: 320–1000 mV at 3 V excitation
Operating Temperature Range: -40–55 °C (-40–131 °F)
Air Temperature Range: -40–55 °C (-40–131 °F)
Air Temperature Resolution: 0.1 °C (0.1 °F)
Air Temperature Accuracy: ±1 °C (±1.8 °F), wind greater
than 7.4 km/h (4.6 mph)
Relative Humidity Range: 10–95% RH
Relative Humidity Accuracy: ±4% RH
Wind Speed Range: 0–144 km/h (0–90 mph)
Wind Speed Accuracy, Low Wind Speed: 0–18.5 km/h
(0–11.5 mph), RMS error of 1.8 km/h (1.1 mph) + 10%
of reading
Wind Speed Accuracy, High Wind Speed: 18.5–144.5
km/h (11.5–90 mph), RMS error of 3.7 km/h (2.3 mph)
or 5% RMS, whichever is greater
Wind Direction Range: to 360°
Wind Direction Resolution: 0.1°
Wind Direction Accuracy, Low Wind Speed: 7.4–18.5
km/h (4.6–11.5 mph), RMS, typical
Wind Direction Accuracy, High Wind Speed: Greater
than 18.5 km/h (greater than 11.5 mph), RMS, typical
NOTE: When wind speed is less than 7.4 km/h (4.6
mph) and (or) air temperature is below 0 °C (32
°F), wind, temperature, and relative humidity
readings are less accurate.
RMS error (root-mean-square error) is a measure
of the differences between values predicted by a
model and values actually observed.
Dimensions, Sensor Body
Diameter, Top: 72 mm (2.83 in.)
Diameter, Nut Assembly, Connection With Sensor
Body: 45 mm (1.77 in.)
Length, Total: 131 mm (5.16 in.)
Length, Sensor Body: 90 mm (3.54 in.)
45-1
102914
PN=33