Campbell Scientific TE525-L Tipping Bucket Rain Gauge
RM72004,0000162 -19-07MAY13-1/1
RM72004,0000166 -19-07MAY13-1/1
RM72004,0000163 -19-29OCT13-1/1
RM72004,0000164 -19-07MAY13-1/1
RM72004,00001A1 -19-07MAY13-1/1
Theory of Operation
The rain gauge measures precipitation (rainfall and
overhead irrigation) in 0.25 mm (0.01 in.) amounts and
sends a signal through the gateway to the John Deere
Field Connect website. The website collects the sensor
signals and presents precipitation amounts up to 100 mm
per hour (4 in. per hour).
Precipitation collects in a bucket that tips when filled to the
calibrated level. A magnet triggers a switch as the bucket
tips. Switch signals are counted to measure precipitation.
PC15761 —UN—24AUG12
Specifications
Switch: Momentary potted reed switch
Average Switch Closure Time: 135 ms
Bounce Settling Time: 0.75 ms
Switch Rating: 30 VDC @ 2 A, 115 VAC @ 1 A
Output Resolution: 0.2 mm (0.01 in.)
Accuracy: 1.0% up to 50 mm/hr. (2 in./hr.)
Operating Environment: 0–50 °C (32–125 °F), 0–100%
relative humidity
Dimensions:
Height, Total: 255 mm (10 in.)
Collector Diameter: 154 mm (6.1 in.) with knife-edge
Funnel Depth: 163 mm (6.4 in.)
Splash Protection: Greater than 50 mm (2 in.)
Cable Length: 6 m (20 ft.)
Connector Type: Molex MX150
Mount Location
NOTE: Before installing rain bucket, remove packaging
that secures tipping mechanism inside rain bucket.
Mount rain bucket in a level spot that is representative
of surrounding area. Install rain bucket so funnel lip is
horizontal and at least 30 cm (12 in.) above ground.
Install rain bucket above average snow depth. Natural
vegetation or gravel surface around rain bucket provides
best results. Avoid placing rain bucket in a paved area.
Place rain bucket away from objects that obstruct wind.
Position rain bucket a distance of 2–4 times height of any
obstruction.
Maintenance
NOTE: Contact your John Deere dealer for
replacement parts.
Check funnel and bucket mechanism. Remove dust,
insects, plant litter, and other material.
External Cleaning Of Probe, Sensors, and
Gateway
IMPORTANT: Field Connect components and
connections may not be weatherproof. Properly
close and latch enclosure cover after any
procedure completed inside enclosure.
Do not use pressure washer or common solvents such
as automotive brake cleaning fluid to clean soil moisture
probe, sensors, or gateway. To remove soil from plastic
components, use a solution of soap and water.