Viewing Environmental Sensor Data
RM72004,00001E9 -19-29OCT13-1/1
View Environmental Sensor Data
NOTE: On Field Connect™ website, assign environmental
sensors to a port on gateway. During Field
Connect™ installation, assign connected sensor
to gateway port. Before installing Field Connect™
gateway, soil moisture probe, and sensors, log in to
website and open Help topics. Review procedures
to assign a sensor to a gateway port. Complete port
assignment, and then continue with field installation.
Sensor output is collected at gateway and transmitted
to Field Connect™ website. To view sensor output, go
to Graph page of http://fieldconnect.deere.com. Log in
with user ID and password. Navigate to Graph page of
appropriate management zone. To view specific sensor
data, select View and Filter Options and Data Layers.
Choose data from list, and select UPDATE DATA.
For more information and help on viewing environment
sensor data, use online Help available in the upper
dropdown menu of website. In Help table of contents,
select Environmental Sensors. Choose from the
environmental sensor topics.
Air Temperature (AIRMAR WeatherStation
150WX Weather Sensor)
•
Unit of Measure: Degrees Celsius (Degrees Fahrenheit)
•
Range: -40—55 °C (-40—131 °F)
•
Precision: XX.X
Humidity (AIRMAR WeatherStation 150WX
Weather Sensor)
•
Unit of Measure: Percent, Relative Humidity
•
Range: 10–95% relative humidity (RH)
•
Precision: XXX.X
Wind Speed (AIRMAR WeatherStation 150WX
Weather Sensor)
•
Unit of Measure: Kilometers Per Hour (Miles Per Hour)
•
Range: 0–144 km/h (0–92 mph)
•
Precision: XX.X
Wind Direction (AIRMAR WeatherStation
150WX Weather Sensor)
•
Range: N, NW, W, SW, S, SE, E, NE
Air or Soil Temperature (Campbell Scientific
Model 107-L Temperature Probe)
•
Unit of Measure: Degrees Celsius (Degrees Fahrenheit)
•
Range: -35—50 °C (-31—122 °F)
•
Precision: XX
Solar Radiation (Campbell Scientific CS300-L
Pyranometer)
•
Unit of Measure: Watts Per Square Meter (Watts Per
Square Foot)
•
Range: 0–1750 W/m
2
(0–162.6 W/ft
2
)
•
Precision: XXX.XX
Leaf Wetness (Campbell Scientific LWS-L
Leaf Wetness Sensor)
•
Unit of Measure: Unitless Reference Value
•
Range: 2,000–12,000
•
Precision: XXX
Precipitation (Campbell Scientific TE525-L
Rain Gauge)
•
Unit of Measure: Millimeters (Inches)
•
Range: 0–100 mm (0–4 in.)
•
Precision: XX.XX
40-1
102914
PN=32