Campbell Scientific Model 107–L Temperature Probe
RM72004,00001E7 -19-08OCT13-1/1
RM72004,000019E -19-07MAY13-1/1
RM72004,000016C -19-07MAY13-1/1
Maintenance
NOTE: Contact your John Deere dealer for
replacement parts.
Temperature probe requires minimal maintenance. For air
temperature measurements, clean radiation shield every
month. Check cables for signs of damage and moisture
intrusion.
External Cleaning Of Probe, Sensors, and
Gateway
IMPORTANT: Field Connect components and
connections may not be weatherproof. Properly
close and latch enclosure cover after any
procedure completed inside enclosure.
Do not use pressure washer or common solvents such
as automotive brake cleaning fluid to clean soil moisture
probe, sensors, or gateway. To remove soil from plastic
components, use a solution of soap and water.
Troubleshooting
NOTE: If troubleshooting indicates sensor damage,
contact your John Deere dealer.
Verify:
power to sensor
correct connections
tight connections
no kinks in harness
Symptom: Incorrect Temperature
Check cable for signs of damage and possible moisture
intrusion.
Symptom: Unstable Temperature
Make sure the clear, shielded wire is connected to
ground and gateway is properly grounded.
50-2
102914
PN=36