Campbell 21X Manual do Operador Página 44

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 191
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 43
SECTION 3. INSTRUCTION
SET BASICS
nested
2
deep
while
the OR construction is
nested
3
deep.
Branching
and loop
nesting
starts
at
zero within
each subroutine
and
then
returns
to
the
previous
level after
returning
from
the subroutine.
Subroutine calls
do not
count as nesting
with
the
above
instructions.
They
have a
separate
nesting limit of
seven
(lnstruction
85, Section
12).
Any number
of
groups
of
nested
instructions
may be
used
in any
of the three Programming
Tables. The
number of
groups
is
only
by the
program
memory
available.
3.9 INSTRUCTION MEMORY
AND
EXECUTION TIME
The
standard 21X has 978 bytes
of
program
memory
available
fbr
the
programs
entered in
the
*1
,
*2,
and
*3
program
tables. Each
instruction
also
makes
use
of
varying
numbers
Input, Intermediate,
and
Final
Storage
The following
tables
list
the memory used
by
each instruction and the
approximate time
required
to execute the
instruction.
TABLE
3.9-1.
InpuUOutput
Instruction
Memory
MEMORY
EXECUTION
TIME
(ms)
PROG. MEASUREMENTRANGE
BYTES 1-4 or NA
5.*
11-14
15 38.0 + 19.2R
8.4 + 3.7R 5.5 + 2.4R
15 36.9
+
38.0R 7.8 +
6.9R
5.5 +
3.7R
15
0.2
+ 1.2R
20 38.0 +
(19.2
+ D)R
8.1
+
(4.4
+ D)R 5.3 +
(2.8
+ D)R
18 38.8
+
40R 10.7
+
7.5R 7.5 +
5.1R
18
41 .8 +
73.0R 10.5
+
13.1 R 7.6 + 7AR
18
41.2+
76.8R
10.6 +
16.2R 7.1 + 11.0R
20 38.1 +
(19.2
+ D)2R
8.1 +
(4.2
+ D)2R
5.3
+
(2.8
+ D)2R
19 76.7 + 149.6R 15.7
+282R 9.9+
16.7R
4 7.6
5.0
+
8.4R
7.9
+
7.0R
40.8 + 23.2R
39.2
+ 42.7R
0.4
+ 2.7R
'14.0
1.4
1200
0.3
10.5
1.0+D
0.54
to reset,
0.25 to load into location
R
=
No. of
Reps.
D
=
Delay
INSTRUCTION
INPUT
LOC.
1
VOLT
(SE)
R
2
VOLT
(D|FF)
R
3 PULSE R
4
EX-DEL-SE R
5 AC HALF
BR
R
6 FULL
BR
R
7
3W
HALF BR
R
8 EX-DEL-DIFF
R
9 FULL
BR-MEX
R
10
BATT.
VOLT
1
11
TEMP
(107)
R
12 RH
(207)
R
13 TEMP-TC
SE R
14 TEMP.TC DIF R
16
TEMP-RTD R
17
TEMP-INTERNL 1
18
TIME 1
19
SIGNATURE 1
20 PORTSET 1
21 ANALOG OUT 1
22
EXCIT-DEL 1
23 BURSTMODE
R
26
TIMER 1 or 0
101
SDM-|NT8 25
102
SDM-SW8
16
103
SDM-AO4 0
104
SDM-CD16 6
15
17
18
18
15
4
7
4
4
5
11
7.9 +
6.7R
7.8 +
8.5R
*
Range
5 uses
a 1 .67ms
integration
time; the other "slow integration"
ranges
(1-4)
use 16.67ms
integrations. Range
15
uses a 25ps integration
(ranges
11
-
14
use
250ps). The execution times for
instructions
using range
15 are faster
than those
given
for ranges
11
-
14
by approximately
225ps
per
for
sinole-ended
3-6
and 4 for
differential.
Vista de página 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 190 191