ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 2
What each sensor is.
When to collect the data from each sensor.
How to process the collected data.
Which data values define a single data record to be logged into logging memory.
When to log into memory and/or transmit the data record.
Whether to generate one or more alarm messages.
Which telephone numbers to dial (up to 4 telephone numbers), if an alarm message is to be sent via a
telephone modem.
What (if any) types of communication devices are connected to the ZENO®-3200 (a one-way radio,
two-way radio, telephone modem, cellular modem, GOES or ARGOS transmitter).
To define the configuration within the ZENO
®
-3200 (and to retrieve data logged), the user interactively
communicates with ZENOSOFT
®
using its built-in user interface. The user interface contains a set of
interactive menus that allow the user to create a new configuration or modify an existing configuration.
1.3. ZENO
®
-3200 SPECIFICATIONS
1.3.1. Analog Inputs
Seven (7) differential or fourteen (14) single-ended inputs offer choices for sampling performance.
Ultra-high resolution: ±18-bit at up to two channels/second with 50/60 Hz noise rejection.
High resolution: ±15-bit at up to 10 channels/second with 50/60 Hz noise rejection.
Low resolution: Two (2) channels available at ±12-bit A/D at 10,000 conversions/second.
Accuracy and linearity are provided over a wide temperature range as follows:
Linearity: ±0.001% (-40°C to +60°C).
Basic radiometric accuracy: ±0.05% (-40°C to +60°C).
Wide dynamic input range: ±5 mV to ±5 V in 10 ranges.
All analog inputs are fault-protected against shorts, overvoltages, transients and ESD.
Up to four multiplexer boards can be added, each allowing 32 additional single-ended or 16
differential inputs.
1.3.2. Digital I/O Ports
Six (6) Schmidt trigger conditioned inputs.
Two (2) comparator inputs.
Six (6) general purpose input or output channels (inputs TTL with pull up resistor, outputs 1 - 5 VDC
high impedance).
One (1) switch closure (event counter).
Digital inputs can be configured for frequency, period, count, or event counting. Digital outputs can
provide control or alarm signals.
Count inputs: Up to 65536 counts at 0.005% accuracy.