ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page C-8
PROCESS MENU
ITEM DATA
COMMAND ENTERED
Item 1: Process Category code = 2 : Meteorological
c1/2
Item 2: Process Type code = 6:Rain Process
c2/6
Item 3: User-defined Process Name = 3: Rain
c3/Rain
Item 4: Input for Rain Gauge = S1:Rain
2
C4/S1
2
Item 5: Accumulation Interval (Hours) = 24
C5/24
Item 6: Accumulation Offset (Hours) = 0
C6/0
Item 7: Sensor Type (1-TB, 2-RMY, 3=ORR) = 1
C7/1
2 This data will vary depending on the number of sensors being connected to the ZENO
.
DATA OUTPUT MENU
Settings for Rain Rate
ITEM DATA
COMMAND ENTERED
Item 1: Field Type code = 9 : Transmit and Log Data Field
c1/9
Item 2: Output Message(s) = 1 DEFAULT
Item 3: Field Name = rr
c3/rr
Item 4: Data Process Record = P1.2
3
c4/P1.2
3
Item 5: Field Decimal Places = 1
c5/1
Item 6: Field Width = 4
c6/4
Item 7: Data Storage Class Code = 7 : Compressed Floating Point (2)
c7/7
DEFAULT = Default Data: it is not necessary to enter a command for this Item.
3 This data will vary depending on the number of sensors being connected to the ZENO
-3200.
Settings for Rain Accumulation
ITEM DATA
COMMAND ENTERED
Item 1: Field Type code = 9 : Transmit and Log Data Field
c1/9
Item 2: Output Message(s) = 1 DEFAULT
Item 3: Field Name = ra
c3/ra
Item 4: Data Process Record = P1.1
4
c4/P1.1
4
Item 5: Field Decimal Places = 1
C5/1
Item 6: Field Width = 4
c6/4
Item 7: Data Storage Class Code = 7 : Compressed Floating Point (2)
c7/7
DEFAULT = Default Data: it is not necessary to enter a command for this Item.
4 This data will vary depending on the number of sensors being connected to the ZENO
-3200.
Vista de página 283