ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page F-16
ERROR14,29^C
10.5. Create Default Configuration
DEFAULTCONFIG
This command causes ZENOSOFT
®
to go to the default configuration—completely deleting the existing
configuration. The default configuration sets all run-time parameters to their default values, all constants
to zero, deletes all sensors, processes, data outputs and GSI scripts. If successful, ZENOSOFT
®
returns a
CCSAIL
OK.
If CCSAIL
ENDSAMPLE has not been previously sent, ZENOSOFT
®
responds with a CCSAIL ERROR
8.
10.6. General Serial Interface (GSI) Commands
393
ADDGSI,n,mmm,
Add a new GSI script before or after script mmm. n is either A for after or B for before. mmm is the
existing GSI script number or
L for last. If successful, ZENOSOFT
®
creates the new GSI script and
returns a CCSAIL
OK. This command can only be sent after the ENDSAMPLE command has been sent.
If CCSAIL
ENDSAMPLE has not been previously sent, ZENOSOFT
®
responds with a CCSAIL ERROR
8.
If
n is neither an A or B, ZENOSOFT
®
will respond with a CCSAIL ERROR 12.
If script number
mmm does not exist, ZENOSOFT
®
will respond with a CCSAIL ERROR 85.
If no more scripts can be added, ZENOSOFT
®
will respond with a CCSAIL ERROR 83.
DELGSInnn,
Delete GSI script number nnn. If successful, ZENOSOFT
®
deletes the desired GSI script and returns a
CCSAIL
OK. If nnn is set to 0, all scripts will be deleted.
If CCSAIL
ENDSAMPLE has not been previously sent, ZENOSOFT
®
responds with a CCSAIL ERROR
8.
393
Refer to Section 12.2.