Use Conditional Start and Conditional Stop Data Output Records (refer to Section 10.6.9) to add
additional information to a regular message for an alarm message.
Transmit a completely different output message for your alarm message.
Log the alarm message.
If you are using a satellite communications link, there are fewer options available to you:
If you are using a GOES transmitter, you are limited to transmitting either regular (self-timed)
messages OR alarm (random) messages ONLY. This is a limitation of the GOES transmitter, not the
ZENO
®
-3200.
231
The ARGOS transmitter does not support alarm (random) messages, only regular (self-timed)
messages.
232
Any alarm message sent to the ARGOS transmitter would only be transmitted as part of
its regular schedule.
233
Further, ARGOS messages are limited to 32 characters.
11.2.1. Transmitting Your Regular Output Message As An Alarm Message
Transmitting (and possibly logging) your regular output message as an alarm message is simply a matter
of setting up the correct process (or processes) that define the alarm condition, then following the
instructions in Section 11.3.
11.2.2. Using Conditional Message Fragments In An Alarm Message
Your regular output message may not contain sufficient information when an alarm condition arises. If
you need to transmit the regular output message information along with the alarm information when an
alarm condition arises, you can set up one or more conditional message fragments to be transmitted by
following the instructions in Section 10.6.9:
Place all alarm information between two Data Output Records set up as Conditional Start and
Conditional Stop field types.
Configure the Data Input (Line Item #4 in the Data Output Menu) in the Conditional Start Data
Output Record to reference the alarm state generated by your alarm condition process.
If you need the alarm message to be transmitted immediately when the alarm condition is met (and
possibly logged), then you need to follow the instructions in Section 11.3. Otherwise, you can simply
have the regular output message transmit at its regular time with the addition of the conditional
message fragment containing the alarm information.
11.2.3. Transmitting A Unique Alarm Message
You may need to transmit completely different information when an alarm condition arises as opposed to
what you would transmit in a regular output message. for this procedure, you will need to use at least two
output messages in which one is designated as the regular output message and the other is designated the
alarm message.
231
Refer to Section 6.7.
232
Refer to Section 6.8.
233
Unlike GOES satellites that sit in geo-synchronous orbits, the ARGOS system is installed on two polar-orbiting
satellites. This means that when an alarm condition occurs, there is a very high probability that no satellite will be
there to receive the alarm message when it occurs.