ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 42
Error Code.
40
You can view the available outputs of any Process Record at any time by typing this
command in any ZENO
®
-3200 menu.
For our example configuration, one more Process Record needs to be defined that will calculate the
average of the Battery Voltage that is read by Sensor Record #2. To do that, we need to insert a new
Process Record after the current one using the A{ENTER} command. Your screen will look something
like this:
> A
PROCESS MENU
(Cn/m) Change Item n To Value m (Jn) Jump To Record n
(A) Insert After This Record (N) Go To Next Record
(B) Insert Before This Record (P) Go To Previous Record
(X) Cut Record to Clipboard (XA) Delete ALL Records
(C) Copy Record To Clipboard (Z) Zeno Program Menu
(V) Paste Record From Clipboard (H) Help
(Sn/m) Search Item n for Value m
Process Items for Record 2 of 2:
Item 1: Process Category 1 : General
Item 2: Process Number 1 : Immediate Data Process
Item 3: User-defined Process Name
Item 4: Input for Immediate Data S0.1
>
The same type of Averaging Process will be used to calculate the average of the Battery Voltage readings
in this Process Record. As in the previous Process Record, Line Item #1 will be set to 1 and Line Item #2
will be set to 2. A good user name for this Process Record could be "AvgBatt," Since you know that the
Sensor Record #2 is where the Battery Voltage data is being collected. Therefore, a single, space-
delimited line, setting three line items at once, can be typed: C2/2 C3/AvgBatt C4/S2{ENTER}.
Your screen should look something like this:
> C2/2 C3/AvgBatt C4/S2
PROCESS MENU
(Cn/m) Change Item n To Value m (Jn) Jump To Record n
(A) Insert After This Record (N) Go To Next Record
(B) Insert Before This Record (P) Go To Previous Record
(X) Cut Record to Clipboard (XA) Delete ALL Records
(C) Copy Record To Clipboard (Z) Zeno Program Menu
(V) Paste Record From Clipboard (H) Help
(Sn/m) Search Item n for Value m
Process Items for Record 2 of 2:
Item 1: Process Category 1 : General
Item 2: Process Number 2 : Averaging Process
Item 3: User-defined Process Name AvgBatt
Item 4: Input for Average Data S2 : Battery
>
Both Process Records needed for our example configuration are now configured.
40
Refer to Section 10.4.5 and Appendix D.
Comentários a estes Manuais