ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048 Page C-21
ITEM DATA
COMMAND ENTERED
Item 1: Process Category Code = 1 : General DEFAULT
Item 2: Process Type code = 11 : Multiple-Input Min/Max
C2/11
Item 3: User-defined Process Name = 3 : cld1min
c3/cld1min
Item 4: Input for Data1 = P2.1 : cld1col
3
C4/P2.1
3
Item 5: Input for Data2 = P2.2 : cld1col
3
C5/P2.2
3
Item 6: Input for Data3 = P2.3 : cld1col
3
C6/P2.3
3
Item 7: Input for Data4 = P2.4 : cld1col
3
C7/P2.4
3
Item 8: Input for Data5 = P2.5 : cld1col
3
C8/P2.5
3
Item 9: Input for Data6 = P2.6 : cld1col
3
C9/P2.6
3
Item 10: Input for Data7 = P2.7 : cld1col
3
C10/P2.7
3
Item 11: Input for Data8 = P2.8 : cld1col
3
C11/P2.8
3
Item 12: Input for Data9 = P2.9 : cld1col
3
C12/P2.9
3
Item 13: Input for Data10 = P2.10 : cld1col
3
C13/P2.10
3
Item 14: Minimum Allowed Value 0.1
C14/0.1
Item 15: Maximum Allowed Value 20000
C15/20000
DEFAULT = Default value: it is not necessary to enter a command for this item.
3 This value will vary depending on the number of sensors being connected to the ZENO
-3200.
ITEM DATA COMMAND ENTERED
Item 1: Process Category Code = 5 : Arithmetic
C1/5
Item 2: Process Type code = 13 : Conditional Select Process
C2/13
Item 3: User-defined Process Name = 3 : cld1
c3/cld1
Item 4: Input for Control Data = P1.2 : noceil1
4
C4/P1.2
4
Item 5: Input for Output if Control=0 (X) P3.2 : cld1min
4
C5/P3.2
4
Item 6: Input for Output if Control<0 (Y) P1.2 : noceil1
4
C5/P1.2
4
Item 7: Input for Output if Control<0 (Y) P3.2 : cld1min
4
C5/P3.2
4
4 This value will vary depending on the number of sensors being connected to the ZENO
-3200.
ITEM DATA COMMAND ENTERED
Item 1: Process Category Code = 3 : Alarm
C1/3
Item 2: Process Type code = 8 : Missing Sensor Data Process
C2/8
Item 3: User-defined Process Name = 3 : cld1z
c3/cld1z
Item 4: Input for Sensor Data P4.1 : cld1
5
C4/P4.1
5
Item 5: Default Data 0 DEFAULT
Item 6: Digital Output Channel 0 DEFAULT
DEFAULT = Default value: it is not necessary to enter a command for this item.
5 This value will vary depending on the number of sensors being connected to the ZENO
-3200.
Settings for Second and Third Cloud Levels