ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 113
COMMUNICATIONS MENU
(Cn/m) Change Item n To Value m (Tn) Terminal Mode On COM Port n
(M) Modem Menu (E) Save Parameters To EEPROM
(P) Power Control Menu (U) User Menu
(G) GOES Menu (Q) Quit
(D) Digital Control Menu (H) Help
Item 1: 9600 (COM1 Baud Rate)
Item 2: 1200 (COM2 Baud Rate)
Item 3: 9600 (COM3 Baud Rate)
Item 4: RS232 (COM1 Port Type)
Item 5: ARGOS (COM2 Port Type)
Item 6: RS232 (COM3 Port Type)
>
Next, enter A from the Communications Menu to enter the ARGOS Menu.
ARGOS MENU
(Cn/m) Change Item n To Value m (Q) Quit
(E) Save Parameters To EEPROM (H) Help
(U) User Menu
Item 1: 42 (Tranmission Repeat Interval, seconds)
Item 2: 1 (Transmision Repeat Count)
Item 3: 10 (Radio Push-To-Talk Delay Time, milliseconds)
Item 4: 0 (Radio Push-To-Talk Digital Port)
Item 5: 0 (Use Hour/Min Time Stamp in Message)
Item 6: 0 (Use Checksum in Final Message Byte)
>
Specify the Transmission Repeat Interval, line item 1. This is a decimal value between 42 and 297
seconds.
Specify the Transmission Repeat Count, line item 2. The maximum number of times that the ST-13
can repeat a message is 255.
Specify the Radio Push-To-Talk Delay Time in milliseconds, line item 3. The range of this value is
10 to 5000 milliseconds.
Specify the Radio Push-To-Talk Digital Port, line item 4. Set this value to 0 to use the ZENO
®
-
3200's built-in PTT line; otherwise, a value of 18 to 23 can be used to specify a digital output line.
Specify whether to use Hour/Min Time Stamp in Message, line item 5. By setting this value to 1,
ZENOSOFT
®
will set the first two bytes of the ARGOS message to the current hour and minute.
Setting this value to 0 will allow the first two bytes to be used for user-specified data.
Specify whether to Use Checksum in Final Message Byte, line item 6. By setting this value to 1,
ZENOSOFT
®
will calculate a modulus-256 checksum of the first 31 bytes of the ARGOS message
and set the 32
nd
byte to the checksum. If the user doesn’t want a checksum, set the value to 0.
The ARGOS transmissions are timed on the transmitter’s clock.