ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 8
4. The ZENO
®
-3200 requires a power source of 10 to16 VDC. You can either apply power to the
ZENO
®
-3200 using the 12 VDC power adapter provided by Coastal Environmental Systems, or you
can connect to your own 10 to 16 VDC power supply. If you are using your own power supply,
connect power to the points labeled "POWER" on the terminal strip labeled "SERIAL DATA,
POWER AND GROUNDS" on top of the ZENO
®
-3200. See Figure 2-3.
Figure 2-3. ZENO
®
-3200 Power Connections & Connecting to COM3.
With the ZENO
®
-3200 properly connected to the computer and the computer is running the terminal
emulation program, upon applying power, you will see the following text generated by ZENOSOFT
®
:
Watchdog Reset
Please wait.../
ZENO-3200 using ZENOSOFT V1.964 Jun 28 2001 15:41:01 CS 96CC
(C)opyright 1995-2001, Coastal Environmental Systems, Seattle, WA, USA.
System Time = 01/07/11 13:47:31
Initializing Zeno 3200 .../
Zeno 3200 is Data Sampling. Type 'U'{ENTER} to access the User Interface.
2.3. ZENO
®
-3200 MEMORY
Before proceeding, a brief discussion is provided to explain the two main types of memory that are used
in the ZENO
®
-3200. The two types of memory are Random Access Memory (RAM) and Electrically
Erasable Programmable Read Only Memory (EEPROM).
COM3 port
Power (+/-)
DC power
lu
+ center
Comentários a estes Manuais