ZENO
®
-3200 USER MANUAL
Coastal Environmental Systems (206) 682-6048
Page 123
REPEATER MENU
(Cn/m) Change Item n To Value m (U) User Menu
(R) Reset All Repeater Values (Q) Quit
(E) Save Parameters To EEPROM (H) Help
Item 1: Repeater Tranmit Delay 0 msec
Item 2: Network Source Address 1
Item 3: Alternative Source Address 10
Item 4: Remote ZENO Address #1 1010
Item 5: Remote ZENO Address #2 1020
Item 6: Remote ZENO Address #3 1030
Item 7: Remote ZENO Address #4 1040
Item 8: Remote ZENO Address #5 -1
Item 9: Remote ZENO Address #6 -1
Item 10: Remote ZENO Address #7 -1
Item 11: Remote ZENO Address #8 -1
To prevent the possibility that a remote ZENO
®
-3200 could respond directly to a host’s command, each
Network Source Address in each remote ZENO
®
-3200 will be set to 500—the address of the repeater
ZENO
®
-3200.
The host sends the CCSAIL message “#10200001DN34<ETX>” to the repeater whose Primary Unit ID is
500. The repeater receives the message over COM1 and recognizes that the message is from the
designated Network Source Address and is intended for a remote ZENO
®
-3200. The repeater changes the
message to ”#10200500DN38<ETX>” and transmits the message back out of COM1. The repeater then
receives the following response through COM1 from the remote ZENO
®
-3200:
“#05001020<CR><LF>212,64<ETX>,” and recognizes that the message is intended for the host. The
repeater changes the received message to “#00011020<CR><LF>212,60<ETX>” and transmits it over
COM1.
If the radio that the ZENO
®
-3200 is using requires a delay, the Repeater Transmit Delay value (Line Item
#1 in the Repeater Menu) can be used to
Delay the transmission of the repeated command to the remote ZENO
®
-3200
And delay the response to the host from the remote communication with sensors directly.
6.11. SPEECH INTERFACE CAPABILITY
Coastal Environmental Systems’ ZENO
®
-3200 data logger, equipped with a speech interface board and
low power (IDC) modem, can provide spoken messages over a telephone connection. The spoken
message is easily configured, using normal English text and data so that the caller is provided with
current conditions without the need for any special equipment other than a standard touch-tone telephone.
When calling a Speech Interface-equipped ZENO
®
-3200, you can
Obtain a custom, spoken report of current output data
Receive data or access the user interface via the data modem
Remotely disable or enable the speech capability