Campbell RF410 Manual de Instruções Página 105

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 104
Appendix F. CR510PB w/ P193 Master to CR205s Network
F-7
FIGURE F-3. P193 Numeric Display
Remote2 and Remote4 are missing in the above network, hence the “0.00”
values and incrementing ResultCodes.
When the CR510PB receives a wireless message from a remote, the
corresponding Result Code Location is set to -1. When Instruction 193 is
executed, the Result Code Location is incremented by 1. Therefore, if
communication is successful, the Result Code Location will be 0 after the
execution of Instruction 193. If data transfer is unsuccessful, the Result
Code Location for the remote that failed will be incremented, and will
continue to increment with each failed attempt.
LoggerNet data collection of the CR510PB will slow somewhat due to the
P193 traffic. For example, it took 5 minutes to collect 61K data points with
a network similar to this Appendix’ network but with RF400
communications instead of COM210, 30 second P193 execution, and 7
remotes.
The RF400 in the above system can be configured with radio power mode
(Standby Mode) of < 24 mA (radio always receiving) or < 4 mA (radio
sleeping, awakening every ½ second). If you substitute a CR510PB with
P196 for a CR205, its RF400 can also be configured for < 24 mA or < 4
ma. If the power budget is not tight, configuring < 24 mA on both ends
improves response times slightly.