PakBus Networking Guide
30
FIGURE 16. Edlog PakBus Datalogger Setup
If you don’t want to change a category, check the “Do not change current
settings” box and when the program compiles in the datalogger, that area will
remain the way it was. Be sure to save/compile the program after making the
PakBus Settings changes before sending to the datalogger.
Notes
Zeroing a PakBus Settings “Communication Interval” will delete the selected
port when the program is compiled and sent to the datalogger.
To insert a row of PakBus Addresses (Address / Swath), place cursor over that
field, right-mouse click, and select “Insert Row.”
Configuring an existing port type will overwrite any previous settings for that
port.
4.1.2 *D PakBus Setup for the CR10X, CR510 and CR23X
You can use Edlog \ Options \ PakBus Settings to configure a dataloggers’s
PakBus settings or you can use a keyboard display to edit *D15, *D18 and
*D19 to accomplish the same thing. *D17 is for viewing a datalogger’s routing
table.
You can configure a datalogger’s PakBus settings anytime after downloading a
PakBus OS, before or after sending the program. The *D settings become part
of the program as soon as you press A. Pressing *0 saves the *D settings to
flash. Current PakBus settings will persist through a new program send if the
new program has no Edlog entered PakBus settings.