Appendix E. CR510PB w/ P190s to CR205s Network
E-2
LoggerNet Device Map
ComPort_1
PhoneBase
PhoneRemote
PakBusPort
CR510PB (PakBus Address = 100)
CR200_1 (PakBus Address = 1)
CR200_2 (PakBus Address = 2)
CR200_3 (PakBus Address = 3)
CR200_4 (PakBus Address = 4)
CR200_5 (PakBus Address = 5)
After once dialing up and connecting in LoggerNet, PakBusGraph will display
the CR510PB and all its CR205 neighbors.
LoggerNet Schedule Tab
Collection Interval – 15 minutes
Primary Retry Intervals – 5 minutes
Number of Primary Retries – 2
Secondary Retry Interval – 60 minutes
RF400 Settings
In a PakBus rf network, all radios are set up with the exact same radio and
network address and hopping sequence.
1. Configure RF400 radio with the same Radio Address, Net Address, and
Hopping Sequence as the CR205s. If there will be no other RF400s in the
area, you can use default settings, otherwise choose some other settings
and configure all alike.
2. Other Settings
Active Interface = “CSDC 7” (7 is default. It could be changed to 8 if no
other peripheral uses 8).
Standby Mode = “< 24 mA always on” (other modes work in some
situations if other network radios are the same).
CR205 Settings and Program
1. Configure all CR205s with the same hopping sequence, radio address, and
network address using the same settings as the RF400 has.
2. Configure each CR205 with a unique PakBus address (“Datalogger
Address” in PakCom) starting with “1” and ending with “5.”
3. Configure CR205 Power Mode = RF_ON.
Configure CR205 Radio Force On = 0.