PakBus Networking Guide
44
Result Codes:
1. –1001 Attempted setting is read only
2. –1002 Out of space in the remote
3. –1003 Syntax error
4. 0 Success
5. >1 Number of communication failures
6.1.9 P199 - Routing Table to Input Locations
Purpose:
Used for trouble-shooting; instruction stores the datalogger’s routing table in
Input Locations.
Example:
3: PakBus - Routing Table Information (P199)
1: 0011 First Loc [ ______________ ]
Three pieces of information are stored:
1 PakBus Address of the destination node
2 PakBus Address of the neighbor used to route to the destination node (this
line not present if destination is a neighbor)
3 Maximum response time metric (in seconds)
Set aside Input Locations equal to the maximum number of routes you expect to
see × 3 (node, neighbor, route metric) + 1 extra for the −1 terminator of the list.
For example, if you expect a maximum of 6 routes, then 6*3 + 1 = 19 Input
Locations.
6.1.10 P224 - Send Table Definitions
Purpose:
To transfer Table Definitions to LoggerNet under datalogger program control
as datagrams per BMP5 Message Type 0x89. Can be used for one way media
like Goes satellite. Other purposes pending.
Example:
P224: Send Table Definitions
01: 17 Local DL Port
02: 0003 PakBus Address; destination
03: 4 Table Number: 0 selects all final storage data tables
100 selects the current data table