PakBus Networking Guide
11
critical). On each CR205 connect a 10K resistor from EX1 to SE1 and a
22K resistor from SE1 to the adjacent
(signal ground). These
resistors simulate a 109 thermister probe at approximately 22 degrees
Celsius.
c. With CR205 cabled to your PC’s COM port, connect with PakCom, click
on Monitor Data Tables, enter an Update in Seconds of “2”, and select
the Public data table. The AirTemp_C that you are measuring or
simulating will be displayed as below.
FIGURE 5. Monitoring CR205
Step 10 – Set up LoggerNet Device Map
a. Close PakCom and any other program that might be using your COM port.
b. Open the LoggerNet Toolbar and click the Setup button.
c. Create this device map:
d. Add a device to the map by highlighting the last device and then right-
mouse click to see available options. Highlight and press the “Rename”
button to edit a default name.