PakBus Networking Guide
42
Example:
4: PakBus - Seconds Until Transmit (P194)
1: 0003 Input Loc with Seconds Until P196 Transmit [ ____ ]
If the host has not been heard (using P193), then the Time Until Transmit is set
at a random time slot within a 1 minute interval.
6.1.5 P195 – Set Clock from Address
Purpose:
Sets local datalogger’s clock from a remote datalogger’s clock after the remote
datalogger executes a P192 to send a Clock Report.
Example:
5: PakBus - Use Remote Clock Report (P195)
1: 0011 Address
The single parameter is the address of the remote datalogger expected to send
Clock Reports.
6.1.6 P196 – Wireless Remote
Purpose:
Used in conjunction with P193 to set up a remote datalogger to act as a wireless
sensor/controller (like a CR205) in a PakBus network communicating in a time
slot dictated by the host datalogger during first successful communication.
Remote uses P194 in conditional statement to time execution of its P196
transferring data to host.
Example:
6: PakBus - Wireless Network Remote (P196)
1: 17 Local DL Port
2: 0006 Master’s PakBus Address
3: 0000 Security
4: 05 Swath to Receive from Master
5: 0011 First Input Loc for Data Received [ Host Data_1 ]
6: 04 Swath to Send to Master
7: 0031 First Input Loc to Send [ Local_1 ]
8: 0041 First Comms Status Result Code Loc [ Result_1 ]